Skip to content
Request a callbackCallback

For developers, building owners and design teams

Fire Strategy Report: What It Covers

Sviatoslav JerdetchiiCEO & Founder of Craftex. Updated , 6 min read

Fire exit keep clear sign on an old black riveted door beside a brick wall

The short answer

A fire strategy report explains how a building keeps people safe in a fire: how they are warned, how they get out, how fire is held back and how firefighters get in. It shows building control how the design meets Part B of the Building Regulations.

  1. It follows the five Part B rules: warning and escape, linings, structure, outside walls and fire service access.
  2. It is written at design stage and read with the drawings by building control.
  3. A planning fire statement and a fire risk assessment are different documents.
  4. Our fire engineers write the strategy and our builders build to it, as one team.

A fire strategy report is the plan for how a building keeps people safe in a fire. It is written while the building is designed, and building control reads it with the drawings. This guide explains what it covers, who needs one and how to get it.

Our engineers write the fire strategy for new buildings, extensions and changes of use, and our builders build to it. Planning a scheme? Discuss your scheme with us before the drawings are fixed.

What a fire strategy report is

The Building Regulations set five fire safety rules, called Part B. A fire strategy report shows, one rule at a time, how your design meets them. It ties the drawings, the materials and the alarm and escape design into one story.

The government's guidance on Part B is Approved Document B. It comes in two volumes: one for dwellings and one for buildings other than dwellings. Our guide to Approved Document B explains both.

Approved Document B says fire safety engineering may be the only practical way to reach a good standard in some complex buildings. It names buildings that mix different uses. In those cases the fire strategy carries most of the weight.

What a fire strategy report covers

Each section of the report answers one of the five Part B rules. The table shows what each rule asks and what the strategy sets out for it.

What a fire strategy report covers, rule by rule
Part B ruleWhat the strategy sets out
B1 Warning and escapeAlarms and detection, escape routes, stairs, travel distances and exits
B2 LiningsWhich wall and ceiling finishes are allowed in each space
B3 StructureHow long the frame must stand, and where walls and floors hold fire back
B4 Outside wallsHow the walls and roof stop fire spreading over the building or to the next one
B5 Fire service accessWhere fire engines park, firefighting stairs, fire mains and water supply

A good report also lists the fire doors, the fire stopping around pipes and cables, and what the building manager must keep working. A strategy for an existing building also records what was found and kept.

Fire strategy drawings

The drawings carry the strategy onto site. They are the architect's plans, marked up by the fire engineer. A builder can see at a glance what each wall, door and ceiling must do.

Green running-man fire exit sign with an arrow, lit on a dark wall
  1. Escape routes. Arrows from every room to a final exit, with the travel distance.
  2. Fire walls and floors. Lines showing which walls and floors hold fire back, and for how long.
  3. Fire doors. Every fire door, with its rating and whether it closes by itself.
  4. Alarms and detection. Where detectors, call points and sounders go.
  5. Fire service access. Where firefighters enter and where the fire main inlets are.

Drawings and report must say the same thing. When they disagree, the builder has to guess. Our fire engineers and architects check one set of drawings together, so nothing is left to guess.

We used Craftex for a shop-to-flat conversion in Chelsea — turning an old retail space into two rental units. Access wasn’t the easiest, but the guys handled it well, no drama. Quote was clear, no hidden extras, and they actually stuck to it, which is rare. Finish came out solid, exactly what we needed for rentals. Joe (PM) kept things ticking and communication was always on point. All in all, smooth job — would use them again for sure.👍

Apartify Estates, Google reviewSee all reviews on Google

Who needs a fire strategy

A new building, an extension or a change of use is building work, so it must meet Part B. Building control may ask for a fire strategy to see how.

  1. Developers. Blocks of flats, mixed-use schemes and conversions.
  2. Owners of offices, shops and hotels. Large changes to the building.
  3. Landlords. Turning a building into flats or a house in multiple occupation.
  4. Schools, care homes and clinics. People there may need help to escape.

Approved Document B changed in 2026. It now recommends more than one common stair in blocks of flats with a storey 18m or more in height. It also adds design rules for evacuation lifts in blocks of flats. Our guide to the second staircase and Gateway 2 explains what that means for a scheme.

Fire strategy, fire statement and fire risk assessment

Three documents with similar names do three different jobs. They are written at different times, for different people.

Fire strategy, fire statement and fire risk assessment compared
DocumentWhenWho it is forWhat it does
Fire statementWith the planning applicationThe council and the Health and Safety ExecutiveCovers fire safety in planning terms for relevant buildings
Fire strategyDuring designBuilding control and the builderShows how the design meets Part B
Fire risk assessmentOnce the building is in useThe responsible personFinds the fire risks to people and the precautions needed

GOV.UK says a fire statement must go in with planning applications for relevant buildings. These are 18m or more in height, or 7 or more storeys, with two or more dwellings or educational accommodation. It covers fire safety principles, site layout, access for fire engines and water supplies.

The fire risk assessment is a duty under the Regulatory Reform (Fire Safety) Order 2005. The responsible person must make a suitable and sufficient assessment of the risks to people. We write fire strategies and fire statements; we do not carry out fire risk assessments.

Higher-risk buildings and the Building Safety Regulator

Some tall buildings go through a stricter approval route. GOV.UK calls them higher-risk buildings: at least 7 storeys or 18 metres high, with 2 or more homes, or a hospital or care home.

Red fire alarm call point and its sign fixed to a bare concrete wall

For these, the Building Safety Regulator approves the building work, not the council. GOV.UK says you must get building control approval from the regulator before starting. So the fire design has to be settled before work can begin.

Handing over fire safety information

The fire strategy does not end on site. Regulation 38 of the Building Regulations covers new buildings, extensions and changes of use of buildings that fall under the fire safety order. The person carrying out the work must give fire safety information to the responsible person.

The deadline is completion, or the day people move in if that comes first. The information covers the design and construction of the building and its fire safety systems. It lets the owner run and maintain the building safely, so keep the strategy and drawings with it.

What a fire strategy report costs

There is no fixed price for a fire strategy. The fee depends on the size, height and use of the building. It also depends on how far the design has got and whether the building is new. A single house extension and a mixed-use tower are very different jobs.

Our fire engineers give you a fixed fee once they have seen the drawings. Send the plans and the planned use. You know the figure before any work starts.

How our team writes your fire strategy

Our fire engineers start from the architect's first layouts, not the final set. Escape routes, stairs and fire walls are cheapest to change while they are still lines on a plan.

Craftex is a team of architects with 50 years of experience, interior designers, engineers and builders.

Our team delivered Sloane Place, a 27-key hotel and cocktail bar, and Leicester One, a 56-room scheme. Buildings like these must meet Part B on every floor. Our builders put in the fire doors, fire stopping and alarms that the strategy names, and fix anything an inspection of existing fire walls finds.

Is your design at concept, planning or tender? Discuss your scheme and our fire engineers tell you what the strategy needs to cover.

What to send us for a fire strategy

  • The architect's plans, sections and elevations, in any format
  • The use of each floor, and how many people it will hold
  • The height of the top floor above the ground
  • For an existing building: photos and any old fire documents
  • Your planning and building control dates, if you have them

Frequently asked questions

Who writes a fire strategy report?

A fire engineer writes it, working from the architect's drawings. Our fire engineers write strategies for new buildings, extensions and changes of use, and work beside the architects who draw them.

Is a fire strategy the same as a fire risk assessment?

No. A fire strategy is written while the building is designed. A fire risk assessment is a duty of the responsible person under the Regulatory Reform (Fire Safety) Order 2005, once the building is in use.

Do I need a fire strategy for an extension or a conversion?

If the work is building work, it must meet Part B. For a larger extension or a change of use, building control may ask how the design does that. Tell us the project and we say what it needs.

What is the difference between a fire statement and a fire strategy?

GOV.UK says a fire statement goes in with some planning applications for buildings of 18m or 7 storeys and more. It covers planning matters such as access for fire engines. The fire strategy is the full design for building control.

How much does a fire strategy report cost?

It depends on the size, height and use of the building and how far the design has got. Our fire engineers give you a fixed fee once they have seen the drawings.

Refer a project

Earn 5–10% lifetime commission

from the revenue we generate from your introduction.

Architects, agents, developers, business owners: anyone can refer. Introduce a client and we pay you on their first project and every project after it, for as long as they work with us. The rate depends on the project and is agreed in writing before work starts.

Rates and conditions apply. See the referral terms.

Want a fire strategy from the team that will build it?

Our fire engineers write the strategy and our builders build to it, so the fire doors, walls and alarms on site match the drawings. Send us your scheme. We reply within one hour, Monday to Saturday, 8am to 6pm.

Reply within 1 hour, Mon–Sat 8am–6pm. Urgent? WhatsApp us for a reply straight away, any day.

WhatsApp us